Pioon UTU
Original price was: $12,500.00.$9,999.00Current price is: $9,999.00.
Welcome to the most cutting-edge era of four wavelength laser. With 405nm new laser wavelength and 4-wavelength laser combination, you can fully unleash whole new levels of UTU dental laser potential—starting the most innovative dental laser in your business, your best choice.
405nm Violet Laser
The primary application of 405nm laser in dentistry focuses on oral diagnosis due to its special ability to induce fluorescence in oral tissue and biomolecules. Oral lesions, abnormalities and dental plaque produced by oral bacteria will exhibit fluorescence under 405nm illumination. Moreover, 405nm violet laser can be used for oral disinfection and root canal treatment, 405nm is a promising alternative method for prevention and/or treatment of endodontic infection.
450nm Blue Laser
450nm blue laser excels in soft tissue cutting/ablation mainly due to its high absorption by hemoglobin and other biological pigments, providing efficient energy transfer and precise cutting. 450nm blue laser significantly reduces bleeding during surgery and minimizes thermal damage to surrounding tissue, making it particularly suitable for precise and minimally invasive medical procedures.
650nm LLLT laser
650nm laser is particularly effective in low-level laser therapy (LLLT), which is utilized to accelerate healing processes, alleviate inflammation, and manage both chronic and acute pain.
980nm Infrared
As a preferred choice for a wide range of dental applications, 980nm is highly effective for cutting and hemostasis, also provides significant antibacterial effects, making it useful in endodontic treatments for sterilizing root canals.
520nm aiming beam
520nm green laser stands out clearly against oral tissues because of the discernible color difference among tissue, blood and aiming beam, enhancing the visibility, and aiding dentists in precision targeting during procedures and compatible with various dental lasers, adding versatility to its use.
- Enhanced visibility: Green lasers are highly visible to the human eye, aiding surgeons in accurately locating and manipulating target tissues during surgery.
- Tissue penetration: The wavelength of green lasers (520nm) allows for deeper tissue penetration, providing clear visualization of deeper structures and facilitating precise anatomical dissection and manipulation.
- Reduced tissue damage: Green lasers have low tissue absorption, which can minimize damage to surrounding tissues during dental surgical procedures, thereby preserving healthy tissue.
- Minimal thermal injury: Green lasers deliver energy more uniformly and can be precisely controlled, reducing the risk of thermal injury during dental surgery and promoting faster postoperative healing.
Top-notch design
Better-quality and higher-degree Aluminum-Magnesium alloy case. A more durable frame of better quality and a higher degree of aluminum-magnesium alloy case used in the UTU, the strength, stability, and durability of UTU is now leading the entire medical laser industry as the top 1 medical equipment quality.

NFC fiber identification system
Auto-identifying system control all types of optical fibers connecting with UTU, maintain the consistency and stability of PIOON accessories and equipment and stop the other brand interference and influence.

Protective lens for laser aperture
For maximum equipment safety and extended service life, UTU features a protective lens between the laser module and its laser aperture, reducing the risk of the laser module burning damaged by dust and dirt to less than 5%.

New doctor-focused UI design
Redesigned and re-innovated into a new doctor-focused user interface, long tested and recognized by professional dentists and medical equipment distributors, the new UI design becomes more concise and intuitive, making UTU easier for dentists to use and reducing unnecessary parameters and pattern interference.

Technical Specification
| Wavelength and operating performance | 450nm +/-20nm / 7.0W 405nm +/-10 / 500mw 650nm +/-10nm / 500mW 980nm/810nm +/-10nm / 12W/10W |
The wavelength and power of a laser determine its clinical application range |
| Laser operating model | Continuous Wave (CW) / Pulse/Super-Pulse | Lasers operating in continuous mode and pulsed mode yield different effects in clinical applications. |
| Pulse width | Minimum 10µs, Precise adjustment | Frequency indicates the number of pulses emitted by a laser per second. |
| Weight | 2KG NW | Lightweight, facilitating portability. |
| Battery Capacity | 3500mAh | Sanyo Lithium-ion batteries provide long-lasting power, ensuring stable operation of the device during extended usage or continuous operation |
| Dimensions | 225mm(l) 150mm(w) 150mm(h) |
The compact design does not occupy much space, making it easy to place. |
The medical laser device complies with the following standards
| IEC 60601-1:2020 | IEC 62366-1:2020 | ISO 14971:2019 |
| IEC 60601-1-2:2020 | IEC 80601-2-60:2019 | ISO 24971:2020 |
| IEC 60601-2-22:2019 | IEC 62304:2015 | ISO 10993-1:2018 |
| IEC 60825-1:2014 | ISO 15223-1:2021 | ISO 14971:2019 |